1、 SCOPE |
Cylindrical cell and its stack-up battery。 |
Model:SPK4000LAHT |
Cell Size:18700crew cut(18.0±0.1×70.0±0.5)(mm)
|
|
|
|
|
|
|
|
|
2 、DATA OF STACK UP BATTERIES |
All data involves voltage and weight to stack-up battery are equal to the value of unit cell |
time the number of unit cell which consisted in the stack-up batteries |
Example :Stack-up batteries consisting three unit cells |
Nominal voltage of unit cell=1.2V |
Nominal voltage of stack-up batteries =1.2V×3=3.6V |
Unless otherwise stated, tests should be done within one month of delivery under the |
|
following conditions: |
|
|
|
|
|
|
|
|
Ambient Temperature :20±5℃ |
|
|
|
|
|
|
Relative Humidity : 65±20% |
|
|
|
|
|
Notes: Standard Charge/Discharge Conditions: |
|
|
|
|
|
Charge: |
400 |
mA(0.1C)× 14 hours |
|
|
|
|
Discharge: |
800 |
mA(0.2C) to 1.0V/cell |
|
|
|
Test |
|
Specification |
Conditions |
Remarks |
Capacity |
|
≥ |
4000 |
Standard Charge Discharge |
up to 3 cycles are allowed |
Open Circuit Voltage(OCV) |
|
≥ |
1.25 |
Within l hour after standard Charge |
|
Internal Impedance |
|
≤ |
18 |
Upon fully charge(lKHz) |
|
High Rate Discharge(1C) |
|
≥ |
45 |
Standard Charge, l hour rest Before discharge by 1C to 1.0V/cell |
up to 3 cycles are allowed |
Charge Retention |
|
≥2600 |
(65%) |
Standard Charge,Storage:28 days,Standard Discharge |
|
IEC Permanent Charge test |
|
|
IEC61951-2(2003)7.4.2.3 |
|
Leakage |
|
No leakage nor deformation |
Fully charged at : |
400 |
mA for |
|
14 |
hrs Stand for 14 days |
Vibration Resistance |
|
Change of voltage should be under 0.02V/cell,Change of impedance should be under 5 milli-ohm/cell |
Charge the battery 0.1C 14hrs,then leave for 24hrs,check Battery before/after vibration,Amplitude 1.5mmVibration 3000 CPMAny direction for 60mins. |
|
Impact Resistance |
|
Change of voltage sho-uld be under 0.02V/cell Change of impedance should be under 5 milli-ohm/cell |
Charge the battery 0.1C 14hrsThen leave for 24hrs,check bat-before/ after dropped,Height 50 cm Wooden board(thickness 30mm) Direction not specified,3 times. |
|
Trickle charge life |
|
≥4 |
0.05C(0~70℃) |
|
5、CONFIGURATION, DIMENSIONS AND MARKINGS |
Please refer to the attached drawing. |
6、EXTERNAL APPEARANCE |
The cell/battery shall be free from cracks, scars, breakage, rust, discoloration, leakage nor deformation. |
7、WARRANTY |
One year limited warranty against workmanship and material defects. |
8、CAUTION |
⑴Reverse charging is not acceptable. |
⑵Charge before use. The cells/batteries are delivered in an uncharged state. |
⑶Do not charge/discharge with more than our specified current. |
⑷Do not short circuit the cell/battery Permanent damage to the cell/battery may result. |
⑸Do not incinerate or mutilate the cell/battery. |
⑹Do not solder directly to the cell/battery. |
⑺the life expectancy may be reduced if the cell/battery is subjected adverse conditions like: |
extreme temperature, deep cycling, excessive overcharge/ over-discharge. |
⑻store the cell/battery uncharged in a cool dry place. Always discharge batteries before bulk |
storage or shipment. |